| AQC-12 |
Air Quality Controller for use with alarm control panels. |
Variable sensitivity , 120 VAC operation. SPDT alarm relay, adjustable time delay on alarm. |
AQC-12 |
AQC-12 |
| AQC-21 |
Air Quality Controller for use with alarm control panels. |
Variable sensitivity , 12-24 VAC or VDC operation. SPDT alarm relay, adjustable time delay on alarm. |
AQC-21 |
AQC-21 |
| AD-1 |
Discontinued |
Variable sensitivity from 25-275 ppm , 12-24 VAC or VDC operation. SPDT alarm relay, one minute time delay on alarm. |
AD-1 |
AD-1 |
| AD-12 |
Discontinued |
High & Low level N.O. alarm relays, 12-24 VAC or VDC operation, special calibrations up to 250 ppm available. |
AD-12 |
AD-12 |
| HD-11 |
Hydrogen Detector for use with alarm control panels. |
Flush mount, 12-24 VAC or VDC operation, SPDT alarm relay, special calibrations available. |
HD-11 |
HD-11 |
| HD-12 |
Hydrogen Detector for use with alarm control panels, dual relay output. |
High & Low level N.O. alarm relays, 12-24 VAC or VDC operation, special calibrations available. |
HD-12 |
HD-12 |
| HD-21-1-BR |
Hydrogen Detector for use with alarm control panels, 120 VAC input. |
120 VAC operation, 85db buzzer, N.O. alarm relay, special calibrations and 220 VAC unit available. |
HD-21-1-BR |
HD-21-1-BR |
| FD-11 |
Discontinued |
Flush mount, 12-24 VAC or VDC operation, SPDT alarm relay, special calibrations available. For CFCs only. |
FD-11 |
Ref |
| FD-12 |
Discontinued |
High & Low level N.O. alarm relays, 12-24 VAC or VDC operation, special calibrations available. For CFCs only. |
FD-12 |
Ref |
| FD-21-1-BR |
Discontinued |
120 VAC operation, 85db buzzer, N.O. alarm relay, special calibrations and 220 VAC unit available. For CFCs only. |
FD-21-1-BR |
Ref |
| FT-11 |
Discontinued |
Dual linear output transducer, 24 VAC or VDC operation, 1-5V or 4-20mA output, range 0-1,000 ppm. For CFCs only. |
FT-11 |
Ref |
| RD-1 |
Discontinued |
Variable sensitivity from 25-275 ppm , 12-24 VAC or VDC operation. N.O. alarm relay. For HCFCs only. |
RD-1 |
Ref |
| RD-2 |
Discontinued |
Customer specified/factory calibrated set point, 12-24 VAC or VDC operation, N.O. alarm relay.? For HCFCs only. |
RD-2 |
Ref |
| ND-1 |
Nitrogen Dioxide detector and ventilation? controller, stand-alone or for use with control systems. |
Digital meter (0-9ppm), meets OSHA standards, adjustable relay set points, NEMA 1 enclosure, 12-24 VAC or VDC operation, SPDT fan relay.? |
ND-1 |
ND-1 |
| ND-2 |
Nitrogen Dioxide detector and transducer, stand-alone or for use with Building Automation Systems. |
Digital meter (0-9ppm), meets OSHA standards, 4-20mA output (0-6ppm), adjustable relay set points, NEMA 1 enclosure, 12-24 VAC or VDC operation, SPDT fan relay. |
ND-2 |
ND-2 |
| DMK-1 |
Duct mounting enclosure that allows all of our detectors to sample air in a duct |
All mounting hardware, exhaust tube, and mounting template included. 7" x 7 1/8" x 4 1/4" |
*** |
DMK-1 |